Philips AR aids spinal surgery in Japan
- October 25, 2022
- Steve Rogerson

Mita Hospital in Tokyo is using Philips’ augmented reality (AR) surgical navigation to treat patients and help bring the benefits of minimally-invasive spine surgery to an ageing population.
ClarifEye provides 3D AR on a Philips interventional X-ray system in a hybrid operating room at the International University of Health & Welfare at Mita Hospital. It helps the hospital’s orthopaedic surgeon Ken Ishii treat patients with spinal stenosis (narrowing of the spaces in the spine) and scoliosis (sideways curvature of the spine) via minimally-invasive image-guided procedures.
Due to its aging population, the number of spine surgeries performed each year in Japan continues to increase. Lumbar spinal canal stenosis, the most common spinal disease, is found in approximately 10.8% of the country’s 70 to 79 year olds. In patients with severe symptoms, surgical procedures are typically performed, including excision of the compressed area and fixation of the bone with screws or other fixtures.
Traditionally, these fixation devices have been placed through a large incision with direct observation of the affected vertebra. However, they are now increasingly being placed via minimally-invasive procedures performed through small incisions, reducing bleeding and soft tissue damage, reducing postoperative pain, and making treatment available to patients at risk from the trauma of open surgery.
Philips’ ClarifEye augmented reality surgical navigation combines 2D and 3D visualisations at low X-ray dose with 3D AR navigation in one system. It helps surgeons define and navigate critical trajectories for precise device placement while avoiding damage to fragile neurological and vascular structures close to the patient’s spine.
“The benefit of performing spine surgery in the hybrid OR includes the ability to acquire 3D CT images at low dose, having a lot of space, and being able to use the large monitor,” said Ishii. “The addition of a new navigation system helps to create an even safer surgical environment. Compared to existing navigation systems, ClarifEye has no reference frame-related errors, and it’s wonderful that it achieves real-time imaging with pedicle segmentation. ClarifEye is a new technology that truly offers minimally invasive surgery for patients and clinical staff.”
Karim Boussebaa, general manager at Philips, added: “Mita Hospital’s positive experience of using ClarifEye to deliver the benefits of minimally-invasive therapy to its spine patients mirrors that of hospitals in Europe and the Middle East who also recently adopted the system. ClarifEye adds a new dimension in surgical precision for patients. It is a great example of how we are innovating procedures and helping clinicians to deliver on the quadruple aim of better health outcomes, improved patient and staff experiences, and lower cost of care.”
ClarifEye’s live-video computer vision and AR technology uses non-invasive position markers applied to the patient’s skin to track patient positioning and overlays the resultant live video onto a 3D cone-beam CT of the patient’s spinal column. It lets surgeons visualise the outside and inside of the patient in the same image, together with the planned and real-time trajectory of a ClarifEye needle, without the need for live X-ray imaging. The system eliminates the cumbersome reference frames used by other systems, giving surgeons unimpeded access to the patient.
Intra-operative image guidance has been shown to increase clinical accuracy and improve outcomes, with patients subject to fewer revision surgeries compared with the previous standard of care. Data published in Scientific Reports demonstrated that in open deformity cases, ClarifEye had a better accuracy than similar surgeries performed by the same surgeon with no help from intra-operative navigation (94% versus 89.6%). In addition, data published in European Spine Journal on the clinical use of ClarifEye for minimal invasive procedures showed a 98% accuracy of pedicle screw placement, which is comparable with values reported in literature for other navigation and robotic systems.